INJ-00018 — semiconductor_restart_surge
Status: EXPIRED · Category: E · Source: auto Fired at: 75.52 h · Duration: 12.0 h · Target: T-E04 Economic impact: $-1,000 /h
Parameters
{
"customer_id": "C-13",
"product": "LIN",
"truck_id": "T-E04",
"driver_id": "D-E01"
}Cascade — 10 agent steps
| # | step | agent | detail |
|---|---|---|---|
| 1 | INJECTION | Injection Engine | semiconductor_restart_surge: fab C-13 restarting after maintenance. LAR and LIN demand doubles for 12h. |
| 2 | MPC_SOLVE | MPC Optimizer | 📐 MPC: Optimal load 83% (4h horizon) | Priority: 3 | Expected margin: $0/h | Reason: All constraints healthy → optimize revenue (+load) |
| 3 | PHYSICS | Physics Kernel | Fab restart requires massive inert gas purge. LAR consumption 2x normal. LIN for cooling 1.5x normal. |
| 4 | PRODUCTION | Production Agent | RAMPING 80%→80% to increase LAR/LIN production. LAR is highest-margin product ($0.65/kg). |
| 5 | TANKS | Tank Inventory Agent | LAR at 46%, LIN at 61%. Fab restart drains LAR tank ~2x faster. LAR adequate for surge. |
| 6 | DISPATCH | Dispatch Agent | Priority LAR dispatch to C-13. All available LAR trucks routed to fab. Other LAR customers deprioritized. |
| 7 | CUSTOMERS | Customer Impact Agent | Fab C-13: $500k+/h revenue at stake. Contamination from gas interruption = wafer scrap. Other LAR customers delayed. |
| 8 | LOSS_MITIGATION | Loss Ledger | 📉 L1: Primary Production Physical Balance — PROC pre-ramps gradually, maintains meter accuracy |
| 9 | ECONOMICS | Economics Agent | Fab restart premium: LAR at 28/h. |
| 10 | RECOVERY | Recovery Planner | 1) Fab purge completes in 12h. 2) Demand returns to baseline. 3) Ramp load back down. 4) Refill LAR tank during off-peak. |
Raw effects
- semiconductor_restart_surge: C-13 has no LIN+LAR — surged LOX instead
- semiconductor_restart_surge: fab C-13 restarting after maintenance. LAR and LIN demand doubles for 12h.
- 📐 MPC: Optimal load 83% (4h horizon) | Priority: 3 | Expected margin: $0/h | Reason: All constraints healthy → optimize revenue (+load)
- Fab restart requires massive inert gas purge. LAR consumption 2x normal. LIN for cooling 1.5x normal.
- RAMPING 80%→80% to increase LAR/LIN production. LAR is highest-margin product ($0.65/kg).
- LAR at 46%, LIN at 61%. Fab restart drains LAR tank ~2x faster. LAR adequate for surge.
- Priority LAR dispatch to C-13. All available LAR trucks routed to fab. Other LAR customers deprioritized.
- Fab C-13: $500k+/h revenue at stake. Contamination from gas interruption = wafer scrap. Other LAR customers delayed.
- 📉 L1: Primary Production Physical Balance — PROC pre-ramps gradually, maintains meter accuracy
- Fab restart premium: LAR at 28/h.
-
- Fab purge completes in 12h. 2) Demand returns to baseline. 3) Ramp load back down. 4) Refill LAR tank during off-peak.