INJ-00006 — tank_pressure_cv_leak

Status: EXPIRED · Category: A · Source: auto Fired at: 27.05 h · Duration: 4.0 h · Target: NE-01 Economic impact: $-400 /h

Parameters

{
  "product": "LAR",
  "leak_rate_pct": 24,
  "plant_id": "NE-01",
  "customer_id": "C-10",
  "truck_id": "T-E02",
  "driver_id": "D-E02"
}

Cascade — 13 agent steps

#stepagentdetail
1INJECTIONInjection EngineLAR tank CV leak at NE-01
2MPC_SOLVEMPC Optimizertank_pressure_cv_leak: LAR vent valve stuck 24% open (MODERATE). Leak rate: 2.4 kg/s.
3PHYSICSPhysics Kernel📐 MPC: Optimal load 83% (4h horizon) | Priority: 3 | Expected margin: $0/h | Reason: All constraints healthy → optimize revenue (+load)
4PRODUCTIONProduction AgentVent valve 24% open — LAR vaporizes and escapes at 2.4 kg/s (8640 kg/h). Boiloff rate 2.5x normal. Tank pressure rising, PSV may lift if valve not isolated.
5TANKSTank Inventory AgentReducing load 80%→77% (3% cut) to slow LAR production into leaking tank. At 77% load, LAR production drops from ~0.0 to ~0.0 kg/s. Less product entering leaking tank = less product lost.
6DISPATCHDispatch AgentLAR tank at 49% (55150 kg). Drain rate: 2.4 kg/s from vent + customer demand + boiloff. At this rate, tank reaches critical 15% in ~3.4h.
7CUSTOMERSCustomer Impact Agent🔀 GCN: Route optimization active — 52-feature node embeddings × learned edge weights. Blending 70% distance + 30% GCN-learned delivery outcome weights.
8LOSS_MITIGATIONLoss LedgerEmergency dispatch triggered via tank.overflow event — HUB agent routes trucks to load LAR and deliver to customers. Maintenance crew also dispatched for valve repair.
9ECONOMICSEconomics AgentDuring vent leak, LAR production is reduced AND inventory is draining. Customers with <2 days inventory are at stockout risk. Priority dispatch to P1 tier. Estimated 4 customers affected.
10RECOVERYRecovery Planner💱 Procurement: Evaluating spot buy/sell — proactive purchase at <1.5d for P1/P2 customers at 2.5x markup (cheaper than 3x emergency). Spot sell if tanks >85% and demand low.
11STEP_10STEP_10📉 L1: Primary Production Physical Balance — SENS detects abnormal boil-off, flags CV leak for inspection
12STEP_11STEP_11Product loss: 2.4 kg/s x 4320/h lost to atmosphere. Load reduction: 80%→77%. Net impact: -$4331/h.
13STEP_12STEP_121) Valve isolation crew en route (ETA 30min). 2) Temporary clamp to reduce leak rate. 3) Full valve replacement takes 2-4h. 4) After repair: ramp load back to 80%, rebuild LAR inventory over 4-6h.

Raw effects

  1. LAR vent valve STUCK OPEN — losing 2.4 kg/s
  2. LAR tank CV leak at NE-01
  3. tank_pressure_cv_leak: LAR vent valve stuck 24% open (MODERATE). Leak rate: 2.4 kg/s.
  4. 📐 MPC: Optimal load 83% (4h horizon) | Priority: 3 | Expected margin: $0/h | Reason: All constraints healthy → optimize revenue (+load)
  5. Vent valve 24% open — LAR vaporizes and escapes at 2.4 kg/s (8640 kg/h). Boiloff rate 2.5x normal. Tank pressure rising, PSV may lift if valve not isolated.
  6. Reducing load 80%→77% (3% cut) to slow LAR production into leaking tank. At 77% load, LAR production drops from ~0.0 to ~0.0 kg/s. Less product entering leaking tank = less product lost.
  7. LAR tank at 49% (55150 kg). Drain rate: 2.4 kg/s from vent + customer demand + boiloff. At this rate, tank reaches critical 15% in ~3.4h.
  8. 🔀 GCN: Route optimization active — 52-feature node embeddings × learned edge weights. Blending 70% distance + 30% GCN-learned delivery outcome weights.
  9. Emergency dispatch triggered via tank.overflow event — HUB agent routes trucks to load LAR and deliver to customers. Maintenance crew also dispatched for valve repair.
  10. During vent leak, LAR production is reduced AND inventory is draining. Customers with <2 days inventory are at stockout risk. Priority dispatch to P1 tier. Estimated 4 customers affected.
  11. 💱 Procurement: Evaluating spot buy/sell — proactive purchase at <1.5d for P1/P2 customers at 2.5x markup (cheaper than 3x emergency). Spot sell if tanks >85% and demand low.
  12. 📉 L1: Primary Production Physical Balance — SENS detects abnormal boil-off, flags CV leak for inspection
  13. Product loss: 2.4 kg/s x 4320/h lost to atmosphere. Load reduction: 80%→77%. Net impact: -$4331/h.
    1. Valve isolation crew en route (ETA 30min). 2) Temporary clamp to reduce leak rate. 3) Full valve replacement takes 2-4h. 4) After repair: ramp load back to 80%, rebuild LAR inventory over 4-6h.