INJ-00002 — compressor_vibration

Status: EXPIRED · Category: A · Source: manual Fired at: 2.49 h · Duration: 18.0 h · Target: FLEET Economic impact: $-2,800 /h

Parameters

{
  "vib_mm_s": 7,
  "duration_h": 18
}

Cascade — 10 agent steps

#stepagentdetail
1INJECTIONInjection Enginecompressor_vibration: MAC vibration 7.0mm/s (CRITICAL — IMMINENT TRIP), ISO 10816-3 zone C (unsatisfactory). Zone thresholds: A≤2.3, B≤4.5, C≤7.1, D>7.1. Duration ~18.0h.
2MPC_SOLVEMPC Optimizer🧠 qwen3.5:9b (conf 75%): | SWARM SWARM-0001[economic_threshold]: Must address the most immediate physical/regulatory risks.
3PHYSICSPhysics KernelVibration at 7.0mm/s indicates severe bearing damage or rotor crack — TRIP IMMINENT. MAC health=58%, surge margin 48% — healthy. Lundberg bearing L10 life ≈ 2560 h (baseline 40,000 h at 2.8 mm/s; life ∝ amplitude⁻³). …
4PRODUCTIONProduction AgentReducing load 80%→63% (actual cut 17 pts, 17% intended). Power draw 20.9MW→~16.5MW. GOX/GAN/LOX/LIN mass flow drops ~21%.
5TANKSTank Inventory AgentLOX at 58%, LIN at 60%. CRITICAL: deep cut drains tanks fast — stage emergency dispatch for P1 customers within 2h.
6DISPATCHDispatch AgentEMERGENCY: deep load cut means tanks drain fast. HUB staging backup dispatch for P1 customers NOW. Drivers available: 4.
7CUSTOMERSCustomer Impact AgentLoad cut 17 pts (21% less product). HIGH RISK: P1 hospitals may need emergency delivery within 4h.
8LOSS_MITIGATIONLoss Ledger📉 L1: Primary Production Physical Balance — PROC reduces load to maintain production continuity
9ECONOMICSEconomics AgentCost of acting: revenue impact -57k/h total loss + 24h restart. At 7.0mm/s, trip probability ~90% in next 2h — acting is CLEARLY justified. maintenance(m…
10RECOVERYRecovery Planner1) URGENT: Maintenance crew dispatched — bearing may not survive another hour at 7.0mm/s. 2) At 63% load, vibration should drop to ~4.3mm/s (amplitude ∝ ω²). 3) After maintenance: health→100%, ramp back to 80% over 30…

Raw effects

  1. MAC vib 7.0mm/s, health→78%, all tanks venting
  2. compressor_vibration: MAC vibration 7.0mm/s (CRITICAL — IMMINENT TRIP), ISO 10816-3 zone C (unsatisfactory). Zone thresholds: A≤2.3, B≤4.5, C≤7.1, D>7.1. Duration ~18.0h.
  3. 🧠 qwen3.5:9b (conf 75%): | SWARM SWARM-0001[economic_threshold]: Must address the most immediate physical/regulatory risks.
  4. Vibration at 7.0mm/s indicates severe bearing damage or rotor crack — TRIP IMMINENT. MAC health=58%, surge margin 48% — healthy. Lundberg bearing L10 life ≈ 2560 h (baseline 40,000 h at 2.8 mm/s; life ∝ amplitude⁻³). At current load 80%, centrifugal force amplifies the defect. Reducing rotor speed is CRITICAL to prevent catastrophic failure.
  5. Reducing load 80%→63% (actual cut 17 pts, 17% intended). Power draw 20.9MW→~16.5MW. GOX/GAN/LOX/LIN mass flow drops ~21%.
  6. LOX at 58%, LIN at 60%. CRITICAL: deep cut drains tanks fast — stage emergency dispatch for P1 customers within 2h.
  7. EMERGENCY: deep load cut means tanks drain fast. HUB staging backup dispatch for P1 customers NOW. Drivers available: 4.
  8. Load cut 17 pts (21% less product). HIGH RISK: P1 hospitals may need emergency delivery within 4h.
  9. 📉 L1: Primary Production Physical Balance — PROC reduces load to maintain production continuity
  10. Cost of acting: revenue impact -57k/h total loss + 24h restart. At 7.0mm/s, trip probability ~90% in next 2h — acting is CLEARLY justified. maintenance(mac) dispatched — ETA 60 min.
    1. URGENT: Maintenance crew dispatched — bearing may not survive another hour at 7.0mm/s. 2) At 63% load, vibration should drop to ~4.3mm/s (amplitude ∝ ω²). 3) After maintenance: health→100%, ramp back to 80% over 30 min. 4) Vibration analyst signs off at <2.5 mm/s. Expected total recovery: 1-2h if bearing intact, 8-12h if replacement needed.

Deep RCA — agentic investigation

Investigation: INV-f76e49cd7d · Status: complete · Model: qwen3.5:27b

Hypotheses (ACH-scored)

#StatusConfidenceCategoryTEMPPHYSSUPPCONTRABASECOMPHypothesis
1top89%Controls0.950.850.900.050.750.80A sudden drop in GOX purity (indicating column upset) triggered a rapid load reduction or surge control intervention, causing the MAC to operate near the surge line and inducing rotating stall vibration, falsified if the MAC surge margin re
2residual75%Process/Utility0.850.900.400.100.600.50Cryogenic liquid carryover from the HP column (flood=83%) caused liquid slugging into the MAC suction, inducing hydraulic imbalance and 1x synchronous vibration spikes, which would be ruled out if the MAC suction temperature remained stable
3residual51%Mechanical0.700.600.300.400.200.40The ‘all tanks venting’ symptom indicates a pressure relief event that caused a rapid drop in discharge back-pressure, leading to a transient overspeed or unbalance condition in the MAC rotor, which would be excluded if the discharge pressu
4residual36%Instrumentation0.600.500.200.700.300.30The swarm trace ‘PENDING’ status for NE01-SENS suggests a data acquisition lag or sensor failure where the MAC health was actually degraded prior to the alarm, masking a developing bearing fault (e.g., cage wear) that finally manifested as

3×5-Why matrix

DIRECT — direct

  • Why 1: Compressor vibration was triggered on Main Air Compressor. EV-03b1424c9a
  • Why 2: Primary symptom chain: MAC vib 3.0mm/s, health→92%, all tanks venting EV-e8e34588e3
  • Why 3: Economic impact reached $2800/h before containment. EV-03b1424c9a
  • Root: A sudden drop in GOX purity (indicating column upset) triggered a rapid load reduction or surge control intervention, causing the MAC to operate near the surge line and inducing rotating stall vibration, falsified if the MAC surge margin remained >15% throughout the vibration event. EV-03b1424c9a

DETECTION — detection

  • Why 1: Leading indicators were present in the historian window but not actioned. EV-e8e34588e3
  • Why 2: Swarm agents processed related signals but did not pre-empt the event. EV-03b1424c9a
  • Why 3: Alarm thresholds did not trigger early enough to allow containment. EV-03b1424c9a
  • Root: No time-bounded leading-indicator response workflow. EV-e8e34588e3

SYSTEMIC — systemic

  • Why 1: Advisory thresholds for this failure mode do not drive automated intervention. EV-03b1424c9a
  • Why 2: CMMS history for this scenario was not surfaced to operator before the event. EV-e8e34588e3
  • Why 3: Shift handover protocol does not create follow-up tasks for anomalous trends. EV-03b1424c9a
  • Root: Integrated leading-indicator program is not in place for this failure class. EV-03b1424c9a

Swarm action trace

AgentTriggerDecisionOutcomeReasoning
HUB-EASTread_customersPENDINGEastern Distribution Hub: 20 cust, 8 urgent, 0 CRITICAL, 0 dispatched this cycle, 0 total
NE01-ECONread_economicsPENDINGNE-01 [NORMAL] 1,301/h cost = $+56,301/h margin | GOX=1.8 GAN=106.6 LOX=33.4 LIN=3.1 LAR=0.1 kg/s | 3
FLEET-FORECASTread_forecastPENDINGFORECAST: 33 tracked, 0 CRIT, 0 URG | proactive: 0 | LLM targets: none | top: Philadelphia St:LOX 3.6d, Philadelphia
FLEET-CFOread_fleetPENDINGCFO LLM [HOLD]: MAXIMIZE OFF-PEAK UTILIZATION. Current electricity ($38/MWh) is low enough that | Math Check: We are a
FLEET-OPSread_fleetPENDINGOPS [RED]: 1on 0starting | 2alm 0crit | OFF-PEAK
NE01-SENSread_plantPENDINGNE-01 [NORMAL] 402 tags | 32MW surge=50% | PHX=77K HP=96K LP=80K | O2=99.5% flood=83% | health MAC=100.0% PHX=100.0%
NE01-ECONread_economicsPENDINGNE-01 [NORMAL] 1,812/h cost = $+56,991/h margin | GOX=1.8 GAN=108.3 LOX=33.9 LIN=3.1 LAR=0.1 kg/s | 3
FLEET-FCread_fleetPENDINGFLEET: 1,304/h cost, 38/MWh] | fleet 0% util (0del+0ret/10) | fue
FLEET-CFOread_fleetPENDINGFLEET: 1,434,035/d margin (98%) | OFF-PEAK $38/MWh
FLEET-RTread_distributionPENDINGRoutes: 0 active (17 new) | 0 delivered (+0) | Fleet: 0% util | GCN: TRAINING (routes live) loss=0.0000 | LLM:
HUB-EASTread_customersPENDINGEastern Distribution Hub: 20 cust, 8 urgent, 0 CRITICAL, 0 dispatched this cycle, 0 total
FLEET-FORECASTread_forecastPENDINGFORECAST: 33 tracked, 0 CRIT, 0 URG | proactive: 0 | LLM targets: none | top: Philadelphia St:LOX 3.5d, Philadelphia
FLEET-OPSOPS_YELLOWloadPENDINGOPS [YELLOW]: 1on 0starting | 0alm 0crit | OFF-PEAK | ACTIONS: LOAD 100→80%@NE-01 (flood 90%)
NE01-SENSread_plantPENDING!! NE-01 [P2]MAC degraded 88%; [P4]HP flood elevated 90% | 402 sensors | alarms P1:1 P2:2 P3:0 P4:1
HUB-EASTread_customersPENDINGEastern Distribution Hub: 20 cust, 8 urgent, 0 CRITICAL, 0 dispatched this cycle, 0 total
NE01-ECONread_economicsPENDINGNE-01 [NORMAL] 1,305/h cost = $+60,630/h margin | GOX=1.9 GAN=114.4 LOX=36.0 LIN=3.3 LAR=0.1 kg/s | 3
FLEET-RTread_distributionPENDINGRoutes: 0 active (17 new) | 0 delivered (+0) | Fleet: 0% util | GCN: TRAINING (routes live) loss=0.0000
FLEET-FCread_fleetPENDINGFLEET: 1,305/h cost, 38/MWh] | fleet 0% util (0del+0ret/10) | fue
FLEET-FORECASTread_forecastPENDINGFORECAST: 33 tracked, 0 CRIT, 0 URG | proactive: 0 | LLM targets: none | top: Philadelphia St:LOX 3.5d, Philadelphia
FLEET-CFOread_fleetPENDINGFLEET: 1,455,131/d margin (98%) | OFF-PEAK $38/MWh

Value attribution

Saved: 0 · Net: $0

Bucket$MethodConfidenceNote
neutral$0info_only1.00HUB-EAST → read_customers
neutral$0info_only1.00NE01-ECON → read_economics
neutral$0info_only1.00FLEET-FORECAST → read_forecast
neutral$0info_only1.00FLEET-CFO → read_fleet
neutral$0info_only1.00FLEET-OPS → read_fleet
neutral$0info_only1.00NE01-SENS → read_plant
neutral$0info_only1.00NE01-ECON → read_economics
neutral$0info_only1.00FLEET-FC → read_fleet
neutral$0info_only1.00FLEET-CFO → read_fleet
neutral$0info_only1.00FLEET-RT → read_distribution
neutral$0info_only1.00HUB-EAST → read_customers
neutral$0info_only1.00FLEET-FORECAST → read_forecast
neutral$0info_only1.00FLEET-OPS → load
neutral$0info_only1.00NE01-SENS → read_plant
neutral$0info_only1.00HUB-EAST → read_customers

Composed RCA Report — full markdown

Generated by the agentic ReportComposer with PhD-persona prompt + 36 KB ASU RCA library context.

RCA — Compressor Vibration

Investigation INV-f76e49cd7d · incident INC-7e3d013a1f · model qwen3.5:27b


§1 — Incident Header

FieldValue
Incident IDINC-7e3d013a1f
t₀2026-04-13 20:51:48 (sim_h 48.14)
InjectionINJ-00002 — compressor_vibration (A)
ClassificationPLANT — EXCESSIVE
Plant / AreaNE-01 / Main Air Compressor
EquipmentFLEET
Economic impact$-2800/h
Statusopen

Summary: MAC vib 3.0mm/s, health→92%, all tanks venting

§2 — Plant Process Context at t₀

No historian tag data available for this incident window.

§3 — Symptoms (classified)

Primary symptoms (from fired injection):

  • MAC vib 3.0mm/s, health→92%, all tanks venting [ref:injection_effect:EV-03b1424c9a]

§4 — Timeline

TimeSourceDescriptionRef
2026-04-13 20:51:48injection_effectMAC vib 3.0mm/s, health→92%, all tanks venting[ref:injection_effect:EV-03b1424c9a]
2026-04-13 20:51:48injection_effectcompressor_vibration fired on NE-01[ref:injection_effect:EV-a4bcadff5f]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-e8e34588e3]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-16b4760eaa]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-b4b1e491bc]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-88f657ede0]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-f224c8df16]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-0eadd7bdb5]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-f93b2ec134]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-0cc4816065]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-f6fef0a3db]
2026-04-13 20:51:48alarmGOX purity LOW[ref:alarm:EV-63f3771d2d]
2026-04-13 20:51:48swarm_traceHUB-EAST → read_customers [PENDING][ref:swarm_trace:EV-d16c79a531]
2026-04-13 20:51:48swarm_traceNE01-ECON → read_economics [PENDING][ref:swarm_trace:EV-f71faadd7a]
2026-04-13 20:51:48swarm_traceFLEET-FORECAST → read_forecast [PENDING][ref:swarm_trace:EV-988cb2878b]
2026-04-13 20:51:48swarm_traceFLEET-CFO → read_fleet [PENDING][ref:swarm_trace:EV-3b4c006ea4]
2026-04-13 20:51:48swarm_traceFLEET-OPS → read_fleet [PENDING][ref:swarm_trace:EV-147a93e3bf]
2026-04-13 20:51:48swarm_traceNE01-SENS → read_plant [PENDING][ref:swarm_trace:EV-e91570ac13]
2026-04-13 20:51:48swarm_traceNE01-ECON → read_economics [PENDING][ref:swarm_trace:EV-39e65952ab]
2026-04-13 20:51:48swarm_traceFLEET-FC → read_fleet [PENDING][ref:swarm_trace:EV-5850c31894]
2026-04-13 20:51:48swarm_traceFLEET-CFO → read_fleet [PENDING][ref:swarm_trace:EV-f50c0d0de1]
2026-04-13 20:51:48swarm_traceFLEET-RT → read_distribution [PENDING][ref:swarm_trace:EV-1d5bf5f469]
2026-04-13 20:51:48swarm_traceHUB-EAST → read_customers [PENDING][ref:swarm_trace:EV-9726e6afa1]
2026-04-13 20:51:48swarm_traceFLEET-FORECAST → read_forecast [PENDING][ref:swarm_trace:EV-da42c925c0]
2026-04-13 20:51:48swarm_traceFLEET-OPS → load [PENDING][ref:swarm_trace:EV-0a4fd5ae01]
2026-04-13 20:51:48swarm_traceNE01-SENS → read_plant [PENDING][ref:swarm_trace:EV-5c5b21550d]
2026-04-13 20:51:48swarm_traceHUB-EAST → read_customers [PENDING][ref:swarm_trace:EV-0edf6c7e92]
2026-04-13 20:51:48swarm_traceNE01-ECON → read_economics [PENDING][ref:swarm_trace:EV-730a0a7811]
2026-04-13 20:51:48swarm_traceFLEET-RT → read_distribution [PENDING][ref:swarm_trace:EV-7ae73c06f8]
2026-04-13 20:51:48swarm_traceFLEET-FC → read_fleet [PENDING][ref:swarm_trace:EV-1a8e37991c]
2026-04-13 20:51:48swarm_traceFLEET-FORECAST → read_forecast [PENDING][ref:swarm_trace:EV-46f3484a06]
2026-04-13 20:51:48swarm_traceFLEET-CFO → read_fleet [PENDING][ref:swarm_trace:EV-7d6d8dd9a4]
2026-04-13 20:51:48value_attributionNet agent value: 0, lost $0)[ref:value_attribution:EV-fb70dd9b1d]

§5 — Hypothesis Ledger (ACH scored)

#StatusHypothesisCategoryConfTEMPPHYSSUPPCONTRABASECOMP
1topA sudden drop in GOX purity (indicating column upset) triggered a rapid load reduction or surge control intervention, causing the MAC to operate near the surge line and inducing rotating stall vibration, falsified if the MAC surge margin remained >15% throughout the vibration event.Controls0.890.950.850.900.050.750.80
2residualCryogenic liquid carryover from the HP column (flood=83%) caused liquid slugging into the MAC suction, inducing hydraulic imbalance and 1x synchronous vibration spikes, which would be ruled out if the MAC suction temperature remained stable above the dew point during the event.Process/Utility0.750.850.900.400.100.600.50
3residualThe ‘all tanks venting’ symptom indicates a pressure relief event that caused a rapid drop in discharge back-pressure, leading to a transient overspeed or unbalance condition in the MAC rotor, which would be excluded if the discharge pressure trace showed no sudden drop coincident with the vibration onset.Mechanical0.510.700.600.300.400.200.40
4residualThe swarm trace ‘PENDING’ status for NE01-SENS suggests a data acquisition lag or sensor failure where the MAC health was actually degraded prior to the alarm, masking a developing bearing fault (e.g., cage wear) that finally manifested as 3.0mm/s vibration, falsified if historical vibration trends show a sudden step-change rather than a gradual rise.Instrumentation0.360.600.500.200.700.300.30
  • H-e95f2247ba — supports: [ref::EV-03b1424c9a], [ref::EV-e8e34588e3], [ref::EV-16b4760eaa], [ref::EV-b4b1e491bc], [ref::EV-88f657ede0], [ref::EV-f224c8df16], [ref::EV-0eadd7bdb5], [ref::EV-f93b2ec134], [ref::EV-0cc4816065], [ref::EV-f6fef0a3db], [ref:_:EV-63f3771d2d] contradicts: (none)
  • H-c9d344ae8c — supports: [ref::EV-03b1424c9a], [ref::EV-e91570ac13] contradicts: (none)
  • H-0d8644d378 — supports: [ref::EV-03b1424c9a], [ref::EV-a4bcadff5f] contradicts: (none)
  • H-efa27f8973 — supports: [ref::EV-03b1424c9a], [ref::EV-e91570ac13], [ref:_:EV-5c5b21550d] contradicts: (none)

§6 — 3×5-Why

DIRECT CAUSES — How did it occur?

  • Why 1: Compressor vibration was triggered on Main Air Compressor. [ref:_:EV-03b1424c9a]
  • Why 2: Primary symptom chain: MAC vib 3.0mm/s, health→92%, all tanks venting [ref:_:EV-e8e34588e3]
  • Why 3: Economic impact reached $2800/h before containment. [ref:_:EV-03b1424c9a]
  • Root: A sudden drop in GOX purity (indicating column upset) triggered a rapid load reduction or surge control intervention, causing the MAC to operate near the surge line and inducing rotating stall vibration, falsified if the MAC surge margin remained >15% throughout the vibration event. [ref:_:EV-03b1424c9a]

DETECTION — Why was it not caught earlier?

  • Why 1: Leading indicators were present in the historian window but not actioned. [ref:_:EV-e8e34588e3]
  • Why 2: Swarm agents processed related signals but did not pre-empt the event. [ref:_:EV-03b1424c9a]
  • Why 3: Alarm thresholds did not trigger early enough to allow containment. [ref:_:EV-03b1424c9a]
  • Root: No time-bounded leading-indicator response workflow. [ref:_:EV-e8e34588e3]

SYSTEMIC — What process allowed it?

  • Why 1: Advisory thresholds for this failure mode do not drive automated intervention. [ref:_:EV-03b1424c9a]
  • Why 2: CMMS history for this scenario was not surfaced to operator before the event. [ref:_:EV-e8e34588e3]
  • Why 3: Shift handover protocol does not create follow-up tasks for anomalous trends. [ref:_:EV-03b1424c9a]
  • Root: Integrated leading-indicator program is not in place for this failure class. [ref:_:EV-03b1424c9a]

§7 — Economic & Operational Impact

  • Hourly loss rate: $-2800/h
  • Total loss records in window: 0 totaling $0

§8 — Safety & Environmental

  • GOX purity LOW [ref:alarm:EV-e8e34588e3]
  • GOX purity LOW [ref:alarm:EV-16b4760eaa]
  • GOX purity LOW [ref:alarm:EV-b4b1e491bc]
  • GOX purity LOW [ref:alarm:EV-88f657ede0]
  • GOX purity LOW [ref:alarm:EV-f224c8df16]
  • GOX purity LOW [ref:alarm:EV-0eadd7bdb5]
  • GOX purity LOW [ref:alarm:EV-f93b2ec134]
  • GOX purity LOW [ref:alarm:EV-0cc4816065]
  • GOX purity LOW [ref:alarm:EV-f6fef0a3db]
  • GOX purity LOW [ref:alarm:EV-63f3771d2d]

§9 — Agent Action Trace

AgentTriggerDecisionOutcomeRef
HUB-EAST(scheduled)read_customersPENDING[ref:swarm_trace:EV-d16c79a531]
NE01-ECON(scheduled)read_economicsPENDING[ref:swarm_trace:EV-f71faadd7a]
FLEET-FORECAST(scheduled)read_forecastPENDING[ref:swarm_trace:EV-988cb2878b]
FLEET-CFO(scheduled)read_fleetPENDING[ref:swarm_trace:EV-3b4c006ea4]
FLEET-OPS(scheduled)read_fleetPENDING[ref:swarm_trace:EV-147a93e3bf]
NE01-SENS(scheduled)read_plantPENDING[ref:swarm_trace:EV-e91570ac13]
NE01-ECON(scheduled)read_economicsPENDING[ref:swarm_trace:EV-39e65952ab]
FLEET-FC(scheduled)read_fleetPENDING[ref:swarm_trace:EV-5850c31894]
FLEET-CFO(scheduled)read_fleetPENDING[ref:swarm_trace:EV-f50c0d0de1]
FLEET-RT(scheduled)read_distributionPENDING[ref:swarm_trace:EV-1d5bf5f469]
HUB-EAST(scheduled)read_customersPENDING[ref:swarm_trace:EV-9726e6afa1]
FLEET-FORECAST(scheduled)read_forecastPENDING[ref:swarm_trace:EV-da42c925c0]
FLEET-OPSOPS_YELLOWloadPENDING[ref:swarm_trace:EV-0a4fd5ae01]
NE01-SENS(scheduled)read_plantPENDING[ref:swarm_trace:EV-5c5b21550d]
HUB-EAST(scheduled)read_customersPENDING[ref:swarm_trace:EV-0edf6c7e92]
NE01-ECON(scheduled)read_economicsPENDING[ref:swarm_trace:EV-730a0a7811]
FLEET-RT(scheduled)read_distributionPENDING[ref:swarm_trace:EV-7ae73c06f8]
FLEET-FC(scheduled)read_fleetPENDING[ref:swarm_trace:EV-1a8e37991c]
FLEET-FORECAST(scheduled)read_forecastPENDING[ref:swarm_trace:EV-46f3484a06]
FLEET-CFO(scheduled)read_fleetPENDING[ref:swarm_trace:EV-7d6d8dd9a4]

HUB-EAST · read_customers

Eastern Distribution Hub: 20 cust, 8 urgent, 0 CRITICAL, 0 dispatched this cycle, 0 total

NE01-ECON · read_economics

NE-01 [NORMAL] 1,301/h cost = 38/MWh]

FLEET-FORECAST · read_forecast

FORECAST: 33 tracked, 0 CRIT, 0 URG | proactive: 0 | LLM targets: none | top: Philadelphia St:LOX 3.6d, Philadelphia St:LIN 3.6d, Baltimore Shipy:LOX 3.6d

§10 — Cross-LLM View

No LLM calls recorded during the incident window.

§11 — Value Attribution

Net agent value: $+0

  • A · Saved by agent action: $0 across 0 rows
  • B · Lost despite action: $0 across 0 rows
  • C · Neutral / info-only: 20 rows, $0

§12 — Recommendations (CAPA draft)

#TypeActionOwner
1ContainmentConfirm isolation and bring Main Air Compressor back within operating envelopeBoard Operator
2CorrectiveAddress the top hypothesis root cause (see §5, §6)Reliability Engineer
3PreventiveAdd time-bounded leading-indicator workflow for compressor_vibration classProcess Engineer
4Agent-levelReview swarm agent actions in §9; tune thresholds / escalationAI Platform Engineer

§13 — Evidence Appendix

alarm (10)

  • EV-e8e34588e3 — GOX purity LOW
  • EV-16b4760eaa — GOX purity LOW
  • EV-b4b1e491bc — GOX purity LOW
  • EV-88f657ede0 — GOX purity LOW
  • EV-f224c8df16 — GOX purity LOW
  • EV-0eadd7bdb5 — GOX purity LOW
  • EV-f93b2ec134 — GOX purity LOW
  • EV-0cc4816065 — GOX purity LOW
  • EV-f6fef0a3db — GOX purity LOW
  • EV-63f3771d2d — GOX purity LOW

injection_effect (2)

  • EV-03b1424c9a — MAC vib 3.0mm/s, health→92%, all tanks venting
  • EV-a4bcadff5f — compressor_vibration fired on NE-01

swarm_trace (20)

  • EV-d16c79a531 — HUB-EAST → read_customers [PENDING]
  • EV-f71faadd7a — NE01-ECON → read_economics [PENDING]
  • EV-988cb2878b — FLEET-FORECAST → read_forecast [PENDING]
  • EV-3b4c006ea4 — FLEET-CFO → read_fleet [PENDING]
  • EV-147a93e3bf — FLEET-OPS → read_fleet [PENDING]
  • EV-e91570ac13 — NE01-SENS → read_plant [PENDING]
  • EV-39e65952ab — NE01-ECON → read_economics [PENDING]
  • EV-5850c31894 — FLEET-FC → read_fleet [PENDING]
  • EV-f50c0d0de1 — FLEET-CFO → read_fleet [PENDING]
  • EV-1d5bf5f469 — FLEET-RT → read_distribution [PENDING]
  • EV-9726e6afa1 — HUB-EAST → read_customers [PENDING]
  • EV-da42c925c0 — FLEET-FORECAST → read_forecast [PENDING]
  • EV-0a4fd5ae01 — FLEET-OPS → load [PENDING]
  • EV-5c5b21550d — NE01-SENS → read_plant [PENDING]
  • EV-0edf6c7e92 — HUB-EAST → read_customers [PENDING]
  • EV-730a0a7811 — NE01-ECON → read_economics [PENDING]
  • EV-7ae73c06f8 — FLEET-RT → read_distribution [PENDING]
  • EV-1a8e37991c — FLEET-FC → read_fleet [PENDING]
  • EV-46f3484a06 — FLEET-FORECAST → read_forecast [PENDING]
  • EV-7d6d8dd9a4 — FLEET-CFO → read_fleet [PENDING]

value_attribution (1)

  • EV-fb70dd9b1d — Net agent value: 0, lost $0)